loading
Inlet well: An overflow port and an inlet gate are set in the inlet well. When the amount of water exceeds the system load or an accident occurs in the treatment system, the inlet gate is closed and the sewage is directly discharged into the river or municipal pipe network nearby through the overflow port.
Grille: Sewage often contains a large amount of debris. In order to ensure the normal operation of the MBR system, various fibers, slag, waste paper and other debris must be intercepted outside the system. Therefore, a grate is set in front of the system, and the grate residue needs to be cleaned regularly.
Regulating tank: The amount and quality of the collected sewage change over time. In order to ensure the normal operation of the subsequent treatment system and reduce the operating load, the amount and quality of the sewage need to be adjusted. The sediment needs to be cleaned regularly in the regulating tank. Generally, an overflow is also set to ensure the normal operation of the system when the load is too large.
Hair collector (applicable to grey water treatment system): In the grey water treatment system, since the collected bathing wastewater contains a small amount of hair and fiber, if it is not cleaned up, it will cause blockage to the water pump and MBR reactor, reduce the treatment efficiency, and may eventually cause the whole system to paralyze. Therefore, a hair filter needs to be installed in the grey water treatment system.
MBR reaction tank: The degradation of organic pollutants and the separation of mud and water are carried out in the MBR reaction tank. As the core part of the treatment system, the reaction tank includes microbial colonies, membrane components, water collection systems, water outlet systems, and aeration systems.
Disinfection device: According to the requirements of water outlet, the system is designed with a disinfection device, which can automatically control the dosage. The currently used disinfection processes include ultraviolet disinfection, chlorine dioxide disinfection, ozone disinfection, etc. Hospitals need to choose according to the characteristics of sewage water quality and discharge volume.
Metering device: In order to ensure the good operation of the system, a certain metering device is required to control the system parameters. The metering control instruments include flow meters and water meters.
Electric control device: The electric control box is installed in the equipment room, mainly controlling the water inlet pump, fan and suction pump.
MBR integrated sewage treatment equipment can be used for decentralized domestic sewage treatment in water source protection areas, domestic sewage in residential areas, office buildings, shopping malls, hotels, restaurants, institutions, schools, military camps, hospitals, farms, etc. and similar industrial organic wastewater (such as organic sewage treatment in textile, beer, leather, food, chemical and other industries)
Hot Tags: Integrated MBR Sewage Treatment Equipments, MBR membrane, MBR membrane module, MBR wastewater treatment plant, MBR filter, New MBR Sewage Water Treatment Plant Package, Industrial Home Use Wastewater System, MBR system, MBR home art collection, China, custom, Customized, OEM, manufacturers, factory, suppliers, manufacturing company